Dry type transformer supplier today: Why should the iron core of the transformer be grounded? Transformer core grounding is for safety and electromagnetic compatibility considerations. On the one hand, grounding the transformer core prevents contact voltages caused by ground faults, which can pose a shock hazard to humans. Because when a ground fault occurs on one side of the transformer, the iron core on the other side may have a voltage in contact with the earth. If it is not grounded, this voltage cannot be released. On the other hand, grounding the transformer core can also reduce electromagnetic radiation interference, especially for radio equipment and communication systems. This is because the current will generate a magnetic field in the iron core. If the iron core is not grounded, this magnetic field may leak into the surrounding environment and interfere with the normal operation of other equipment. In conclusion, grounding the transformer core is a protective measure against shock hazards and electromagnetic interference. Find additional information on transformer lamination.
Adopt energy-saving measures: During the operation of the transformer, energy-saving measures can be adopted, such as adopting a high-efficiency cooling system, reducing the load rate of the transformer, optimizing the operation scheduling of the transformer, etc., to reduce energy loss and improve efficiency. Regular maintenance and overhaul: Regular maintenance and overhaul of transformers can maintain the normal operation and stability of transformers, thereby reducing energy loss and improving performance. Choose the appropriate transformer connection method: Different connection methods of the transformer will also affect the performance of the transformer. When choosing a transformer connection method, the optimal connection method can be selected according to actual needs and load characteristics to improve efficiency. To sum up, improving transformer efficiency can be achieved by optimizing design, selecting high-quality materials, adopting energy-saving measures, regular maintenance and overhaul, and selecting appropriate connection methods. In practical applications, various factors need to be considered comprehensively to select the most suitable method for improving performance.
Poor power quality can severely impact the performance of transformer equipment, leading to a variety of negative outcomes. These consequences not only affect the operational efficiency of the equipment but also pose significant economic concerns. One of the primary damages caused by poor PQ is the deterioration of the transformer’s health. Poor PQ, characterized by factors like voltage sags, swells, harmonics, and transients, can cause excessive heating in transformers. This undue heat can degrade the insulation material used in transformers, subsequently reducing their lifespan and potentially leading to catastrophic failures. Therefore, poor power quality can lead to considerable damage to transformer equipment, resulting in economic losses, reduced energy efficiency, and decreased productivity. Therefore, maintaining high power quality is crucial for the optimal performance of transformer equipment and overall operational efficiency.
The cut to length line is a special equipment for the production of transformer core, is our latest generation of cross shear line. This cut to length production line is used for shearing, O punching and V notch of transformer core sheet. The special point of this ctl line is that two O punch and one V notch can work at the same time to produce transformer core pieces with 3, 5, 7 steps in vertical direction and 3, 5, 7 steps in horizontal direction.
CANWIN is not just a length lines company, but also electrical equipment manufacturer. It is the legend of people who have forged their lives with faith and action. CANWIN electrical machinery equipment manufacturing deploys an innovation chain through the industrial chain.Equipment sales can provide integrated solutions; can provide OEM/ODM services to global transformer manufacturers; can provide raw material supply to transformer manufacturers. In the form of cooperation and mutual benefit, set up the transformer manufacturing center and core processing base in the Middle East, India. Dubai. Vietnam. Thailand. etc.
The cooling methods are divided into natural air cooling (AN) and forced air cooling (AF). When air cooled naturally, the transformer can run continuously for a long time under rated capacity. When forced air cooling, transformer output capacity can be increased by 50%. Suitable for intermittent overload operation, or emergency overload operation; Because the load loss and impedance voltage increase greatly during overload, it is in non-economic operation state, so it should not be in continuous overload operation for a long time.Welcome to inquiry price for dry type substation transformer.
Box transformer (usually referred to as “box transformer”) is a compact complete set of power distribution equipment composed of high-voltage power equipment, power transformer, low-voltage electrical equipment and auxiliary equipment. Canwin, a professional box transformer manufacturer & supplier, which focuses on the substation type transformer and traditional box type transformer design in the box shell, A box type transformer is an electronic device that transforms power into alternating current for the purpose of transferring power from one point to another.With small volume, light weight, low noise, low loss, high reliability. Transformer box is widely used in residential areas, commercial centers, light stations, airports, factories and mines, enterprises, hospitals, schools and other places.
The manufacturing technology and product quality of electrical steel plate is one of the important signs to measure the development level of special steel production and science and technology in a country. At present, the quantity, quality and specification of cold rolled electrical steel in China cannot meet the needs of energy (power) industry development, and there is a big gap between China and Japan in terms of production technology, equipment, management and scientific research.Canwin is one of the most professional silicon steel sheet suppliers in China, which has been specialized in silicon steel manufacturing for over 20 years.Contact us, we are the best choice. Discover even more information on canwindg.com
Transformer application of aluminum foil to make dry type transformer has small volume, light weight, good insulation performance, flame retardant, no pollution, little partial discharge, moisture proof, stable and reliable operation, low noise, low maintenance cost advantages, in the high-rise building, underground facilities, business center, residential, hotels and humid coastal areas and other applications.Want to konw composition of aluminum foil, please contact Canwin, one of the best copper foil suppliers & manufacturers in China, specialized in aluminium copper foil and transformer copper foil for over 20 years. With the rapid development of laser machines technology and equipment, it is more and more widely used in various fields. At present, most hardware products still use argon arc welding and other welding methods in production and processing.
The main pillar of the smart grid is the smart substation, which is not only an important hub for power transmission and distribution, but also directly affects the operational and monitoring capabilities of the smart grid through its operational safety and stability. Through the network, information can be exchanged, and the transformer can share information with the process layer and the station control layer. On the premise of ensuring product performance, the integration of monitoring, control, measurement, protection, and metering is designed to achieve the integration of transformer components with actuators, sensors, and transformers.
Insulation level: There are standards for insulation levels. The insulation level of a transformer with a rated high voltage of 35 kV and a rated low voltage of 10 kV is represented as LI200AC85/LI75AC35, where LI200 indicates that the transformer has a high-voltage lightning impulse withstand voltage of 200 kV, a power frequency withstand voltage of 85 kV, and a low-voltage lightning impulse withstand voltage of 75 kV, and a power frequency withstand voltage of 35 kV. The current insulation level of Aux High-Tech Co., Ltd.’s oil-immersed transformer products is LI75AC35, indicating that the transformer has a high-voltage lightning impulse withstand voltage of 75 kV and a power frequency withstand voltage of 35 kV. Because the low voltage is 400 V, it can be ignored.